TEL: +86-158-5877-7327
Compare metal and plastic tension clamp bodies only after confirming that both proposed designs suit the same cable system and mechanical duty. A metal body is not automatic evidence of higher usable load, and a plastic body does not automatically mean a light-duty fitting.
A dead end tension clamp also contains gripping elements and attachment hardware. An aluminum-bodied design can use polymer wedges, while a polymer-bodied design can still have a metal bail. The useful comparison is how the complete assembly transfers load and protects the cable, not which material is most visible.
“Metal tension clamp” and “plastic tension clamp” describe a material choice. “Wedge” and “bolted” describe mechanical arrangements. These are separate decisions: a wedge system can operate inside a metal or polymer body, and the presence of a bolt does not identify how the cable is gripped.
In a wedge design, movement of the gripping parts within the body develops pressure around the intended cable surface. Its geometry, contact length, material, and permitted cable range determine whether it can hold the specified load without unacceptable slip or damage.
A bolted arrangement depends on its approved gripping geometry and tightening requirements. It should not be replaced by a wedge design, or vice versa, on appearance alone. A bolted clamp expressly designed for insulated cable is also different from a bare-conductor fitting that merely looks similar.

PAL1500 from CONWELL’s website. A metal-bodied clamp can include polymer gripping parts, so material assessment must cover each component.
| Decision point | Metal-bodied route | Polymer-bodied route | Evidence needed |
|---|---|---|---|
| Load transfer | Review alloy, body geometry, gripping parts, and attachment. | Review resin, reinforcement, geometry, and attachment. | Performance for the specified cable and complete assembly. |
| Insulation contact | Identify the wedges, liners, or jaws between cable and body. | Identify which surfaces grip the cable and how pressure is distributed. | Cable-range, slip, and insulation-damage acceptance criteria. |
| Outdoor deterioration | Check corrosion, finish, and dissimilar-metal interfaces. | Check UV, moisture, temperature, and sustained-load behavior. | Applicable environmental and mechanical evidence. |
| Installation control | Do not infer a tightening method from body material. | Do not infer tool-free installation from a plastic appearance. | Model-specific instructions, tools, orientation, and checks. |
| Mounting interface | Review bail, hook, pin, bracket, and fixing. | Review the same interfaces, including metal attachments. | Compatible hardware and an approved load path. |
The ABC dead-end clamp range contains different constructions and applications. Do not turn the category’s material labels into a universal ranking of strength or service life.
An insulated-neutral-messenger clamp grips a particular load-bearing member. A self-supporting two-core or four-core clamp has a different cable-contact arrangement. Phase count alone does not tell the buyer which member the clamp must hold.
CONWELL lists PAL1000 and PAL1500 as metal tension clamps. Its insulated-neutral-messenger anchoring clamp, PAL1500, is specifically described for that cable system. PA2/35 is listed with a two-core configuration, while NES-1S is listed with a four-core configuration. These references are not alternatives simply because their bodies contain metal.

PA2/35 assembly example from CONWELL’s website. Compare the cable-contact arrangement with the cable drawing, not just the body finish or family name.
CONWELL identifies PA16~95 as a plastic tension clamp. The polymer-bodied clamp information provides an initial reference, but its public description mixes suspension and tension wording. Obtain the current application drawing and confirmed mechanical duty before treating it as a replacement for a messenger or multi-core dead end.
If an RFQ specifies PA50 or NLL, request the exact variant, construction drawing, and approved conductor application. Their current model-specific evidence was not verified for this comparison. Do not assume either is suitable for the same ABC arrangement, or substitute a bare-conductor design for an insulated-cable fitting.
A minimum breaking load, a cable-slip result, and an allowable working load are different quantities. A clamp may remain intact while the cable slips or its insulation suffers unacceptable damage. A body-strength figure alone does not resolve those failure modes.
Ask for evidence identifying the cable construction and dimensions, the applied load and duration, conditioning, slip limits, and the criteria for cable damage. Where the specification requires it, evaluate retained performance after environmental aging or temperature exposure.
Use design loads established for the actual span, line angle, wind, ice where relevant, and termination arrangement. The responsible designer must apply the project’s design factors. Do not convert a catalog breaking load into a working limit by applying an arbitrary percentage.
Include the attachment system in the review. CONWELL’s aerial cable accessories solution can help organize the component discussion, but clamp, bail, bracket, pole fixing, and supporting structure still need compatible requirements. A suspension assembly is not an automatic substitute for a terminal anchoring assembly.
For a metal body, specify the alloy or grade and relevant surface treatment. Check exposed joints, damaged finishes, and compatibility with adjoining hardware. A metal body may still depend on polymer wedges whose temperature and aging performance require review.
For a polymer body, request the material specification and evidence relevant to UV, moisture, operating temperature, and prolonged loading. Ask how deformation or creep is addressed under the specified service conditions. A black surface or a generic “UV-resistant” claim is not a product-specific durability result.
Plastic bodies do not remove corrosion concerns from metal bails, pins, hooks, or brackets. Nor does an insulating body establish a live-working protection rating. Assess the installed assembly rather than assuming that either material eliminates an entire hazard.
For wedge designs, confirm cable placement, wedge engagement, orientation, and attachment requirements from the manufacturer’s instructions. For bolted gripping designs, obtain the specified hardware and tightening controls. Do not import a torque value or installation method from another model.
Check access for the required tools, bail fit at the hook, freedom from unintended side loading, and whether the existing bracket and pole fixing remain suitable. Retrofit approval should cover the changed load path, not just whether the new clamp fits the old hole.
Installation must follow the utility’s approved work method and site safety controls. This comparison is not a procedure for installing or replacing a clamp on an energized line.
Is a metal tension clamp always stronger than a plastic one?
No. Compare documented performance for the same cable and duty. Different geometry, gripping parts, and attachment hardware prevent a material-only ranking.
Does a wedge clamp have to use a plastic body?
No. Wedge action and body material are separate choices. Identify the body, gripping parts, and attachment individually.
Can a bolted clamp be used on insulated ABC?
Only if that specific construction is approved for the cable. An insulated-cable design should not be confused with a bare-conductor fitting.
Can two clamps with the same breaking load be substituted?
Not on that figure alone. Verify cable compatibility, slip and damage criteria, environmental conditions, installation requirements, and the complete mounting interface.
For a dead end tension clamp RFQ, send the cable construction, load-bearing member, core count, insulated diameters and sections, design loads, environment, mounting drawing, and quantities. Identify whether the request is a new design or a replacement for an existing fitting.
Ask CONWELL to compare clamp constructions for your cable and design load. Request a response explaining the proposed grip mechanism, body and contact materials, supporting test evidence, mounting compatibility, and installation controls. Approve the structure against those requirements before completing the detailed size selection.
Written by the CONWELL international trade team, led by Matt, General Manager, who brings more than 20 years of international trade experience and deep expertise in the power fittings industry. He also leads CONWELL's CNAS laboratory, overseeing product testing, quality control, and technical compliance.
TEL: +86-158-5877-7327
No. 16, Waixi Road, Lingang Economic Development Zone, Yueqing Bay Port Area, Yueqing City, Wenzhou City, Zhejiang Province, China
COPYRIGHT © 2025 ZHEJIANG KEYI ELECTRIC GROUP CO., LTD. ALL RIGHTS RESERVED.
We value your privacy
We use cookies to enhance your browsing experience, serve personalised ads or content, and analyse our traffic. By clicking "Accept All", you consent to our use of cookies.
Customise Consent Preferences
We use cookies to help you navigate efficiently and perform certain functions. You will find detailed information about all cookies under each consent category below.
The cookies that are categorised as "Necessary" are stored on your browser as they are essential for enabling the basic functionalities of the site. Show more
Necessary cookies are required to enable the basic features of this site, such as providing secure log-in or adjusting your consent preferences. These cookies do not store any personally identifiable data.
Functional cookies help perform certain functionalities like sharing the content of the website on social media platforms, collecting feedback, and other third-party features.
Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics such as the number of visitors, bounce rate, traffic source, etc.
Performance cookies are used to understand and analyse the key performance indexes of the website which helps in delivering a better user experience for the visitors.
Advertisement cookies are used to provide visitors with customised advertisements based on the pages you visited previously and to analyse the effectiveness of the ad campaigns.