For a flat FTTH drop, select the fiber optic dead end clamp by the cable’s width, thickness, and load-bearing construction before comparing model names. Then check the route tension and the complete attachment to the pole or building. A clamp that accepts the cable’s dimensions has passed a fit screen, not a complete mechanical or optical assessment.
This guide addresses flat subscriber drop cables at terminal poles, building approaches, and other designed anchor points. It does not approve round ADSS clamps for flat cable or establish that ODWAC-22 and ODWAC-22S are interchangeable.
Do not reduce a flat cable to one “diameter.” Submit width and thickness separately, with units, tolerances, and the orientation shown in the drawing. A notation such as 2 × 6 mm needs a defined order; it is not a 2–6 mm round-cable range.
The cross-section should identify the optical element, strength members, and any separate messenger. A clamp intended to grip the cable body and one intended to anchor a messenger use different load paths. Neither the FTTH label nor the fiber count establishes which arrangement is suitable.
| Cable feature | What to submit | Selection consequence |
|---|---|---|
| Outer profile | Width × thickness, tolerances, and cross-section drawing. | The intended grip must accommodate the profile in its specified orientation. |
| Jacket | Material and exact cable construction or supplier reference. | Dimensional fit alone cannot establish resistance to slip or damaging compression. |
| Strength system | Location and type of strength members; messenger details if present. | Confirm which part the clamp is designed to hold. Do not improvise a messenger separation method. |
| Cable limits | Permitted installation and service tensions, bend limits, and environmental conditions. | Check the cable and fitting together; a stronger clamp does not raise the cable’s allowable tension. |
Use CONWELL’s fiber optic dead-end and tension clamp range to identify the appropriate family, then request confirmation for the actual flat cable. A circular groove’s diameter range cannot be converted into flat-cable compatibility by matching width alone.
The two references are useful starting points for an inquiry, but the suffix is not an engineering specification. Do not assume that “S” establishes a stainless steel grade, a higher load rating, or a particular bail arrangement.
CONWELL’s public ODWAC-22/26 listing identifies ODWAC-22 and shows a 2 × 6 mm cable entry and a 1 kN breaking-load field. Treat these as preliminary catalogue information: confirm dimension order, allowable cable construction, and the test basis in a current drawing. Verified CONWELL data for ODWAC-22S was not available for this comparison, so no numeric rating is assigned to it here.
| Comparison field | ODWAC-22 review | ODWAC-22S review |
|---|---|---|
| Cable fit | Resolve the listed 2 × 6 mm notation against the cable drawing and permitted tolerances. | Obtain a model-specific width/thickness window and supported cable constructions. |
| Mechanical qualification | Clarify what the published 1 kN breaking figure represents and which cable or fixture was tested. | Request the load classification and supporting results; do not inherit ODWAC-22 values. |
| Body, gripping parts, and bail | Confirm the exact supplied assembly and material specification. | Compare the drawing and material specification rather than interpreting the suffix. |
| Replacement decision | Use as a candidate only when fit, load, optical performance, and attachment checks pass. | Keep substitution on hold until the same checks can be completed with traceable evidence. |
When comparing two flat cable dead-end assemblies, require the same project duty and acceptance criteria, not necessarily identical body dimensions. A change in bail length or grip design needs an interface review even when both clamps accept the nominal cable size.
Provide the span length together with cable mass, the required sag or tension basis, support height differences, route direction changes, and applicable wind or ice conditions. Span alone does not define the force at an anchor. The cable supplier or route designer should establish the installation and service load cases.
Keep three quantities separate: the fitting’s breaking load, its permitted working duty where defined, and the cable’s allowable tension. Do not treat a breaking figure as a continuous working load or calculate a universal allowable span from it. Apply the project’s required safety basis without inventing a common percentage for every cable and clamp.
Telenco’s anchoring and suspension guide separates flat, round, and figure-8 cable solutions and addresses cable bending and bail geometry. Its product-specific span tables apply to its own configurations; they do not supply missing ratings for CONWELL ODWAC models.

Shared-pole attachment context from the CONWELL website. This is not an ODWAC installation photograph or evidence of a particular flat-drop cable arrangement.
A suitable cable grip can still leave an unacceptable anchoring assembly. Check bail opening and closure, hook or eye dimensions, bearing surfaces, movement clearance, and the direction in which the cable pulls. Confirm that the bail remains retained under the route’s expected movement without forcing it into an unintended bend.
Review the matching fiber cable brackets and hooks with the mounting method. On poles, identify the pole material, dimensions, and approved band or bolt arrangement. On walls, identify the structural substrate and the specified anchor system; do not assume a fitting intended for a concrete pole can be attached to any facade with the same fastener.

A CONWELL pole bracket illustrates the attachment side of the assembly. Confirm the chosen ODWAC bail, attachment point, and mounting specification together; this image does not prove compatibility or load capacity.
At a building entry, preserve the cable manufacturer’s bend limits between the grip, any slack arrangement, and the entry fitting. The optical connector or termination enclosure should not become the unintended span anchor. Corning’s OptiTip handling procedure identifies excessive pulling, bending, and crushing as cable-damage risks. Its installation details remain specific to the documented cable assembly.
For a first order or a change between ODWAC variants, agree on an evaluation using the actual cable, jacket, clamp build, and mounting arrangement. Define the mechanical and optical acceptance criteria before the evaluation. Check for slip, jacket damage or deformation, correct seating, and optical change using the project-approved method. A hand pull or an empty-clamp strength result does not close these checks.
Can a round ADSS clamp replace a flat FTTH drop clamp?
Not on the basis of an overlapping size alone. The gripping profile and load path must be suitable for the actual cable, with evidence for the intended duty.
Is ODWAC-22S automatically stronger than ODWAC-22?
No such conclusion can be drawn from the suffix. Compare controlled drawings and test information for the exact CONWELL builds before approving a replacement.
Does a 1 kN breaking-load entry mean the cable can carry 1 kN continuously?
No. Establish the permitted service duty, test configuration, cable limits, and project safety basis separately. The catalogue breaking field is not a working-tension approval.
What should a distributor do when two drop cables have the same dimensions?
Check whether their jacket and strength-member constructions are also covered by the proposed clamp’s qualification. Keep different cable references identifiable in the RFQ rather than grouping them by size alone.
To request a fiber optic dead end clamp for a flat FTTH route, send CONWELL your flat-drop anchoring requirements: the cable data sheet and cross-section, width and thickness, jacket and strength-member details, span schedule and design loads, pole or wall attachment drawing, quantities, and target market. State whether ODWAC-22 or ODWAC-22S is mandatory or only a reference. Ask for the proposed assembly drawing and any outstanding qualification information before ordering a substitute.
Written by the CONWELL international trade team, led by Matt, General Manager, who brings more than 20 years of international trade experience and deep expertise in the power fittings industry. He also leads CONWELL's CNAS laboratory, overseeing product testing, quality control, and technical compliance.
TEL: +86-158-5877-7327
No. 16, Waixi Road, Lingang Economic Development Zone, Yueqing Bay Port Area, Yueqing City, Wenzhou City, Zhejiang Province, China
COPYRIGHT © 2025 ZHEJIANG KEYI ELECTRIC GROUP CO., LTD. ALL RIGHTS RESERVED.
We value your privacy
We use cookies to enhance your browsing experience, serve personalised ads or content, and analyse our traffic. By clicking "Accept All", you consent to our use of cookies.
Customise Consent Preferences
We use cookies to help you navigate efficiently and perform certain functions. You will find detailed information about all cookies under each consent category below.
The cookies that are categorised as "Necessary" are stored on your browser as they are essential for enabling the basic functionalities of the site. Show more
Necessary cookies are required to enable the basic features of this site, such as providing secure log-in or adjusting your consent preferences. These cookies do not store any personally identifiable data.
Functional cookies help perform certain functionalities like sharing the content of the website on social media platforms, collecting feedback, and other third-party features.
Analytical cookies are used to understand how visitors interact with the website. These cookies help provide information on metrics such as the number of visitors, bounce rate, traffic source, etc.
Performance cookies are used to understand and analyse the key performance indexes of the website which helps in delivering a better user experience for the visitors.
Advertisement cookies are used to provide visitors with customised advertisements based on the pages you visited previously and to analyse the effectiveness of the ad campaigns.